fire pump set

1. When the pipeline fire pump noise occurs, the most likely fault is the imbalance of the fire pump rotor. Since the water output of the fire pump mainly depends on the high-speed rotation of the rotor, when the rotor is unbalanced for some reason, it will cause the fire pump to deviate from the original rotation track during the rotation process, resulting in the fire pump appearing in the pipeline. When judging the failure of the rotor, it is mainly to replace the rotor of the pump or make a balance hole on the rotor blade of the pump to find out the balance difference.

2. The production noise of the fire pump pipeline has a certain effect. For example, forcing a small flow of a pipe “fire pump” to increase power to increase the original flow will create vibrations in the fire pump. Therefore, whether you use a pipeline fire pump or other types of water pumps, you should follow the water pump use standards to prevent the water pump from making noise, which will affect the service life of the water pump. The solution is to use the pump according to the instructions. If the efficiency of use is affected, it is recommended to replace the appropriate pipeline “fire pump” for use.

3. The installation did not meet the standards, resulting in abnormal noise from the pipeline fire pump. Fire pumps and fire hydrant pumps vibrate at a high frequency during operation, so they must be fixed during installation. If the bolt between the pump body and the base or between the base and the base is loose when installing the pipe fire pump, the transmission shaft between the pump body and the motor of the pipe pump will be bent. It lowered the concentricity and caused an imbalance in the fire pump rotor. This is one of the noise phenomena of fire pumps. In order to improve this phenomenon, the pump shaft of the fire pump needs to be balanced and then reinstalled. Finally, the base of the pump was reinforced.

4. Blockage of the impeller passage can also cause fire pump noise. When the internal flow channel of the fire pump is blocked by foreign matter, it will cause uneven resistance of the fire pump impeller and vibrate the fire pump. Therefore, it is necessary to regularly disassemble and maintain the fire pump to prevent foreign matter from blocking the pipeline.

5. The bearing of the fire pump is damaged. Bearing damage generally does not occur on the main body of an in-line fire pump. If there is a problem with the quality of the pump, or because some hard objects enter the pump body of the tube pump, the bearing is damaged, and the rotor is unstable at first. Causes noise from pipeline fire pumps.

6. Finally, cavitation, cavitation occurs in any type of pump, but some are obviously not noticeable. If cavitation occurs, consider raising the fire pump or increasing the pressure in the piping. If the cavitation phenomenon cannot be changed, the fire pump model needs to be redesigned and replaced.

What kind of terrain to choose what kind of water pump

This problem, in short, is the selection of water pumps. The following are the applicable way for you to choose water pumps from zjbetter. I hope they can help you choose water pumps and help you better. Choose the water pump that suits your design.
1. Confirm the use terrain
First understand the terrain in which the outfit is used, including temperature, moisture, air pressure, air cattiness, dustproof and leakproof conditions, and the position of dangerous areas.
2. Confirm operating conditions
Refers to the liquid face pressure( absolute) on the suction side of the liquid, the liquid face pressure on the discharge side, intermittent or nonstop work, fixed or mobile position, and the convenience of installation and conservation.
3. Confirm the nature of the medium
Medium temperature, viscosity, density, impregnated vapor pressure, solid flyspeck periphery and content, gas content, cattiness, volatility, trap, toxin.
4. elect the material of the pump bathe corridor
According to the physical and chemical parcels of the pumped medium above, the material of the inflow- passing corridor is determined.
5. Determine performance parameters
The performance parameters of the water pump can be determined by computation, analogy, test and other styles.
6. Determine the installation type
The installation of the channel is determined by the layout of the channel and the installation point, and there are direct connection, perpendicular and other types.
8. Determine the number of pumps
In general, spare pumps, especially fire pumps, are set up, and the number of pumps is named according to different situations.

There are numerous ways to maintain fire pumps and water pumps. The following styles are more effective. You can use them for reference
System 1 The installation of the pump set should be accurate and dependable, and there should be no egregious vibration duringoperation.However, or the bearing is hot to the touch( the temperature is advanced than 60 °C) and the water seepage in the seal of the pump shaft is further than 60 drops per nanosecond, the cause must be set up out and the fault should be excluded in time, If the pump makes abnormal noise when pumping water.
the
system 2 Screws that are squinched daily, similar as packing gland screws, irrigation entrapments,etc., should be disassembled with a suitable wrench and a reasonable necklace. You can put some slicking oil painting on it or wipe it regularly with an oil painting cloth to help rust; if the water drain screw isn’t used constantly, it’s easy to rust, so after buying a new water pump, you should first wind the water drain draw, and apply some machine oil painting and white lead oil painting on the screw thread, Change the new oil painting two or three times a time in the future.
the
System 3 If the pump is waxed with machine oil painting, the slicking oil painting should be replaced once a month; if it’s waxed with adulation, it should be replaced every six months. It should be noted that the water pump uses calcium- grounded grease, and the motor uses sodium- grounded grease, and they shouldn’t be used inaptly. Because sodium- grounded grease is hydrophilic, it’ll emulsify into froth and dissipate when it encounters water on the pump, while calcium- grounded grease is hysterical of high temperature, so it’s easy to melt when the temperature rises when used on a motor.

system 4 Don’t pump water with too important beach, so as to avoid unseasonable wear and tear of the impeller, mouth ring and shaft, and try to help water deficit operation. Running without water will damage the water seal, and the water pump is prone to water leakage or indeed no water.
System 5 After the irrigation and drainage season is over, the water pump should be precisely gutted and auditedimmediately.However, they should be repaired or replaced in time, and the corridor that should be waxed should be filled with suitable oil painting; Stylish stored in a dry place, If any damaged or misshaped corridor are set up to be unworkable.