Diesel Engine Multistage Fire Pump

Flow :5~180L/S
Pressure:1.0~2.4MPa
Power:20~630kW
Working Pressure:≤2.5MPa

Rated 4.8/5 based on 277 customer reviews
Share:
Previous:
Content
Better( China)Technology Group Co, LTD. manufactured diesel driven fire pump manufactured according to GB6245-2006 fire pump design. Meets the latest certification CCCF requirements and obtain the certificate. The products’ advantage is that when there’s fire, power failure and the electric fire pump can’t work properly, diesel fire pump automatically put into operation to ensure fire fighting normally; Second, compared with the advantages of electric fire pump, diesel engine pump doesn’t need long-term investment in power supply, saving electricity supply transformer and normal expenses. Diesel Fire Pump configure various automatic functions to meet the requirements of national standards to ensure the long-term normal standby equipment, ready to work at any time. The fire fighting pump systems also apply to other emergent and standby occasions.
Inquiry


    More Diesel engine fire pump

    Generally speaking, we recommend that where natural ventilation is used to install diesel engine fire pumps, there must be vents and exhaust ports of sufficient size, and the position of the vents ensures that there is enough fresh air to supply the diesel engine for combustion within the temperature limit. Of course, the water supply radiator can also be used to take away the heat of the circulating cooling water and the heat emitted from the surface of the unit. If the space cannot meet the requirements of natural ventilation and cannot effectively dissipate heat, it is recommended that you adopt forced ventilation, install an intake fan and an exhaust fan at the vent, and choose a location that can provide enough cold air for the diesel engine and take away the machine room hot air inside. Generally speaking, the air intake of the unit should be 6-7 times that of the diesel engine. Only in this way can normal ventilation be ensured and the operating efficiency of the equipment can be improved.

    In addition, it must be fixed firmly so that the entire unit can be supported to ensure that the unit is in a horizontal state and absorb vibration. Generally speaking, the foundation of the unit adopts a concrete structure. The length and width are 150-250mm on one side of the length and width of the unit chassis, and the depth is 300-600mm. The height of the anchor bolts should be about twice the bolt diameter. And there should be a 750mm channel on both sides and front of the unit to facilitate the operator’s inspection and general maintenance.