Home » Fire Pump Set » Diesel fire pump from our factory is a good choice

Diesel fire pump from our factory is a good choice

Diesel engine fire pumps are relatively common in life, and their performance requirements are relatively high. In normal use, more attention must be paid to maintenance to prolong the service life of the pump. Because diesel fire pumps are not omnipotent, there will be some problems in daily use, so when choosing equipment, we must pay attention to whether the quality of the equipment has reached the national standard. As fire equipment, all kinds of equipment must be Ensure performance, avoid affecting use in disasters and delay rescue.

Rated 5/5 based on 281 customer reviews
Share:
Content

Advantages of diesel engine fire pumps:
1. The function of the diesel fire pump is very powerful. We can set the control time during use, for example: preheating in advance, pre-lubrication or timing start. The use of high technology has made some complicated and time-consuming things easier. The preheating setting in advance has greatly reduced the preparation time for rescue, allowing firefighters to rescue at the first time. In the face of disasters, time is money, time It is life.
2. By adjusting the speed of the engine, the head and flow can be controlled, and the height and size of the water flow will become easier to control. When the nozzle is in a stable state, we can accurately spray water at the fire point to extinguish the fire by controlling the engine, which also reduces the difficulty of firefighters’ rescue.

Inquiry


    More Fire Pump Set

    1. When the pipeline fire pump noise occurs, the most likely fault is the imbalance of the fire pump rotor. Since the water output of the fire pump mainly depends on the high-speed rotation of the rotor, when the rotor is unbalanced for some reason, it will cause the fire pump to deviate from the original rotation track during the rotation process, resulting in the fire pump appearing in the pipeline. When judging the failure of the rotor, it is mainly to replace the rotor of the pump or make a balance hole on the rotor blade of the pump to find out the balance difference.

    2. The production noise of the fire pump pipeline has a certain effect. For example, forcing a small flow of a pipe “fire pump” to increase power to increase the original flow will create vibrations in the fire pump. Therefore, whether you use a pipeline fire pump or other types of water pumps, you should follow the water pump use standards to prevent the water pump from making noise, which will affect the service life of the water pump. The solution is to use the pump according to the instructions. If the efficiency of use is affected, it is recommended to replace the appropriate pipeline “fire pump” for use.

    3. The installation did not meet the standards, resulting in abnormal noise from the pipeline fire pump. Fire pumps and fire hydrant pumps vibrate at a high frequency during operation, so they must be fixed during installation. If the bolt between the pump body and the base or between the base and the base is loose when installing the pipe fire pump, the transmission shaft between the pump body and the motor of the pipe pump will be bent. It lowered the concentricity and caused an imbalance in the fire pump rotor. This is one of the noise phenomena of fire pumps. In order to improve this phenomenon, the pump shaft of the fire pump needs to be balanced and then reinstalled. Finally, the base of the pump was reinforced.

    4. Blockage of the impeller passage can also cause fire pump noise. When the internal flow channel of the fire pump is blocked by foreign matter, it will cause uneven resistance of the fire pump impeller and vibrate the fire pump. Therefore, it is necessary to regularly disassemble and maintain the fire pump to prevent foreign matter from blocking the pipeline.

    5. The bearing of the fire pump is damaged. Bearing damage generally does not occur on the main body of an in-line fire pump. If there is a problem with the quality of the pump, or because some hard objects enter the pump body of the tube pump, the bearing is damaged, and the rotor is unstable at first. Causes noise from pipeline fire pumps.

    6. Finally, cavitation, cavitation occurs in any type of pump, but some are obviously not noticeable. If cavitation occurs, consider raising the fire pump or increasing the pressure in the piping. If the cavitation phenomenon cannot be changed, the fire pump model needs to be redesigned and replaced.

    What kind of terrain to choose what kind of water pump

    This problem, in short, is the selection of water pumps. The following are the applicable way for you to choose water pumps from zjbetter. I hope they can help you choose water pumps and help you better. Choose the water pump that suits your design.
    1. Confirm the use terrain
    First understand the terrain in which the outfit is used, including temperature, moisture, air pressure, air cattiness, dustproof and leakproof conditions, and the position of dangerous areas.
    2. Confirm operating conditions
    Refers to the liquid face pressure( absolute) on the suction side of the liquid, the liquid face pressure on the discharge side, intermittent or nonstop work, fixed or mobile position, and the convenience of installation and conservation.
    3. Confirm the nature of the medium
    Medium temperature, viscosity, density, impregnated vapor pressure, solid flyspeck periphery and content, gas content, cattiness, volatility, trap, toxin.
    4. elect the material of the pump bathe corridor
    According to the physical and chemical parcels of the pumped medium above, the material of the inflow- passing corridor is determined.
    5. Determine performance parameters
    The performance parameters of the water pump can be determined by computation, analogy, test and other styles.
    6. Determine the installation type
    The installation of the channel is determined by the layout of the channel and the installation point, and there are direct connection, perpendicular and other types.
    8. Determine the number of pumps
    In general, spare pumps, especially fire pumps, are set up, and the number of pumps is named according to different situations.