Home » Fire Pump Set » Cutting-Edge EDJ Fire Pump Set for Critical Fire Defense

Cutting-Edge EDJ Fire Pump Set for Critical Fire Defense

The EDJ (Diesel Pump: XA pump, Electric Pump: XA pump )Diesel Engine Fire Pump System is a powerful and reliable firefighting equipment designed for fire suppression and emergency rescue operations. It boasts high-performance capabilities in water extraction and pressure delivery, enabling rapid supply of large volumes of water. The system operates independently, ensuring its reliability even in challenging situations. With its lightweight and portable design, coupled with versatile functionality, the EDJ Diesel Engine Fire Pump System is suitable for various scenarios. Whether you are part of a fire department or an industrial enterprise, the EDJ Diesel Engine Fire Pump System is your indispensable rescue partner.

Rated 4.6/5 based on 529 customer reviews
Share:
Content

1.Powerful Performance: Equipped with a dependable diesel engine, the EDJ Fire Pump System provides abundant power to rapidly supply large volumes of water, ensuring outstanding fire suppression capabilities.

2.Effective Rescue: With its high-performance water extraction and pressure delivery capabilities, the EDJ Fire Pump System effectively controls fire spread, enabling you to swiftly extinguish fires and carry out emergency rescue operations with confidence.

3.Independent Operation: The EDJ Diesel Engine Fire Pump System operates independently, guaranteeing stability and reliability, so you can tackle emergency firefighting demands under any circumstances.

4.Flexibility and Portability: Designed to be compact, the EDJ Fire Pump System is easily deplorable and user-friendly. Its lightweight and portable nature empower you to access powerful firefighting support whenever and wherever needed.

5.Versatile Operations: With features such as automatic startup, remote control, and water supply for firefighting hoses, the EDJ Fire Pump System caters to diverse emergency requirements, ensuring efficient and seamless operations.

 

Whether you are part of a fire department, an industrial facility, a construction site, or a rural area, the EDJ Diesel Engine Fire Pump System is an indispensable firefighting asset. Count on the EDJ Fire Pump System to provide reliable support and swift containment of fires!

Inquiry


    More Fire Pump Set

    The minimum fire rated pressure of ED small fire fighting package set water supply equipment is 3 bar and the minimum fire rated capacity is 25 GPM. ED small fire fighting package set water supply equipment includes at least two power or power source driven pumping units, pressure tanks, pipes, valves and accessories, measurement and control instruments, control cabinets, outdoor rain cover, etc.
    Motor: Three-phase asynchronous squirrel-cage motor independently developed and manufactured by our company, which can be controlled in production time and greatly shorten the whole set production time.
    Diesel Engine: According to the different parameters of customers, we will choose diesel engines with high cost performance ratio. The main brands are QuanChai, Weichai, ShangChai, FAWDE, Cummins, etc.
    Electric Pumps: Electric pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Diesel Pumps: Diesel pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Electronic Components: The main electric components is CHNT, if Schneider or other brand electrical are need, should mention it before place the order.
    Safety Valve plays a safety protection role in the system. When the system pressure exceeds the prescribed value, the safety valve opens, and a part of the gas/fluid in the system is discharged into the atmosphere/pipeline, so that the system pressure does not exceed the allowable value, so as to ensure that the system does not cause accidents due to excessive pressure.
    Pressure Tank: Water is a non-compressible medium. Generally speaking, the pressure drop of fire-fighting pipe network is normal. However, the pressure drop is very slow, the total loss of water in the pipe network isnot large, and the frequent change of pressure in the pipe network leads to frequent start-up and shutdown of pumps. Especially when the power of equipment is high, it will cause great impact on pressure sensors, relaysand motors, thus affecting the performance and life whole equipment. Therefore, it is necessary to choose the right volume of the pressure tank.

    What kind of terrain to choose what kind of water pump

    This problem, in short, is the selection of water pumps. The following are the applicable way for you to choose water pumps from zjbetter. I hope they can help you choose water pumps and help you better. Choose the water pump that suits your design.
    1. Confirm the use terrain
    First understand the terrain in which the outfit is used, including temperature, moisture, air pressure, air cattiness, dustproof and leakproof conditions, and the position of dangerous areas.
    2. Confirm operating conditions
    Refers to the liquid face pressure( absolute) on the suction side of the liquid, the liquid face pressure on the discharge side, intermittent or nonstop work, fixed or mobile position, and the convenience of installation and conservation.
    3. Confirm the nature of the medium
    Medium temperature, viscosity, density, impregnated vapor pressure, solid flyspeck periphery and content, gas content, cattiness, volatility, trap, toxin.
    4. elect the material of the pump bathe corridor
    According to the physical and chemical parcels of the pumped medium above, the material of the inflow- passing corridor is determined.
    5. Determine performance parameters
    The performance parameters of the water pump can be determined by computation, analogy, test and other styles.
    6. Determine the installation type
    The installation of the channel is determined by the layout of the channel and the installation point, and there are direct connection, perpendicular and other types.
    8. Determine the number of pumps
    In general, spare pumps, especially fire pumps, are set up, and the number of pumps is named according to different situations.