Fire Pump Equipment Supplier

The fire pump set adopts ISW pump, which saves cost and is reasonably priced. This series of fire pump sets are suitable for fire protection occasions such as warehouses, docks, airports, petrochemicals, power plants, liquefied gas, textiles, ships, and oil tankers.

Rated 5/5 based on 419 customer reviews
Share:
Content

Fire pump set consists of one main pump coupled to electric motor, one stand by pump coupled to diesel engine, jockey pump, pressure vessel, controller for manual or automatic operation of system and standard accessories mounted on base frame.

1.Electric pump ,can use single stage pump, horizontal split case pump, end suction pump, multistage pump, material can be cast iron, stainless steel, and bronze impeller

2.Diesel engine pump, with capacity and head equal to electric pump, with fuel tank, water tank, fan, control box

3.Jockey pump, horizontal or vertical, capacity will be small, but head should be higher than electric and diesel engine pump

4.Control panel: Auto control of electric pump, diesel engine pump and jockey pump with overload, over current protection

5.Accessories: check valve, gate valve, pressure vessel, generally 0.6mpa, 1.0mpa, 1.6 mpa, Pressure gauge, Pressure sensor, common pipe for suction and discharge, Flexible joints and flanges, common base plant

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.