The diesel engine fire pump is suitable for unattended emergency water supply systems. The product has the characteristics of good technology, high degree of automation, superior performance, complete protection functions, reasonable structure, simple installation, and high cost performance. pipe network pressure.

Rated 5/5 based on 342 customer reviews
Share:
Content

1. Automatic preheating: make the diesel engine fire pump in the standby state of the heat engine to ensure emergency work;
2. Direct connection type: The diesel engine and the water pump used in the diesel water pump unit below 360kw are directly connected through the elastic coupling technology, which reduces the failure points, greatly shortens the starting time of the unit, and increases the reliability and emergency performance of the unit;
3. Users can also request to set other alarm outputs;
4. Automatic start: After the diesel water pump unit receives a fire alarm/pipe network pressure/power failure/or other start signals, it can automatically start within 15 seconds and put into full-load operation;
5. Automatic charging: the battery can be automatically charged by the mains or diesel charging motor to ensure the smooth start of the unit;
6. Automatic alarm: automatic alarm protection for diesel engine low oil pressure, high water temperature and other faults, alarm and stop when over speed.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.