Small EEJ Fire Pump Set

The small EEJ fire pump set is suitable for low buildings. The fire pump set consists of two ISW electric pumps and one CDL jockey pump. The ISW pump is easy to install and maintain, no need to disassemble or move the piping system, just lift the pump to connect the flat nut All rotor parts can be removed. The impeller is directly mounted on the main shaft of the motor, with a short axial dimension and a compact structure, which can calibrate the rounding of the pump to effectively generate radial and axial loads, thereby ensuring smooth operation, vibration and low noise of the pump.

Rated 4.5/5 based on 217 customer reviews
Share:
Content

1. Electric pump, can use multistage pump, material can be cast iron, stainless steel, and bronze impeller

2. Jockey pump, horizontal or vertical, capacity will be small, but head should be higher than electric and diesel engine pump

Jockey material casing: cast iron ,shaft and impeller SS304

3. Control panel: Auto Control of electric pump and Jockey Pump with overload, over current protection.

The control system has current, voltage, power display, and the operating status display of fire pump and steady pressure pump, oil pressure, speed, running time display, manual pump control and automatic remote control

5. Accessories: check valve, gate valve, pressure vessel, generally 0.6mpa, 1.0mpa, 1.6mpa, Pressure Gauge, Pressure Sensor, Common Pipe for Suction and Discharge, Flexible Joints and Flanges, Common Base plant

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.

    Translated with www.DeepL.com/Translator (free version)