Composition and application of diesel engine water pump for fire pump set

The diesel engine-powered water pump of the fire pump set is composed of horizontal centrifugal pumps, diesel engines, electrical instruments and other equipment, which are tightly installed on a common chassis, and connected with the electric control box through control lines and signal lines. The complete set of water supply equipment for diesel engines can be used in various enterprises. The production of automatic/manual water supply systems can also be used for fire water supply and occasions with special requirements.

Rated 4.8/5 based on 347 customer reviews
Share:
Content

Application of fire pump diesel engine pump:

1. It is used as a backup main pump for fire fighting, called diesel engine fire pump;

2. For industrial emergency purposes, such as boiler water supply, high temperature water supply, etc.;

3. Used for agricultural irrigation in areas without power supply.

 

Inquiry


    More Diesel engine fire pump

    Generally speaking, we recommend that where natural ventilation is used to install diesel engine fire pumps, there must be vents and exhaust ports of sufficient size, and the position of the vents ensures that there is enough fresh air to supply the diesel engine for combustion within the temperature limit. Of course, the water supply radiator can also be used to take away the heat of the circulating cooling water and the heat emitted from the surface of the unit. If the space cannot meet the requirements of natural ventilation and cannot effectively dissipate heat, it is recommended that you adopt forced ventilation, install an intake fan and an exhaust fan at the vent, and choose a location that can provide enough cold air for the diesel engine and take away the machine room hot air inside. Generally speaking, the air intake of the unit should be 6-7 times that of the diesel engine. Only in this way can normal ventilation be ensured and the operating efficiency of the equipment can be improved.

    In addition, it must be fixed firmly so that the entire unit can be supported to ensure that the unit is in a horizontal state and absorb vibration. Generally speaking, the foundation of the unit adopts a concrete structure. The length and width are 150-250mm on one side of the length and width of the unit chassis, and the depth is 300-600mm. The height of the anchor bolts should be about twice the bolt diameter. And there should be a 750mm channel on both sides and front of the unit to facilitate the operator’s inspection and general maintenance.