Small EDJ Fire Pump Set

The fire pump system includes diesel engine pump + electric motor pump + jockey pump.
Its power: 1.0 to 20kw, flow: 15-300gpm, head: 3-10bar, 50/60hz. Material: Cast iron or SS, bronze impeller.
This pump set is ideal for fire protection or voltage stabilization in houses or small buildings. We customize according to NFPA 20 and GB standards.

Rated 4.6/5 based on 528 customer reviews
Share:
Content

2. Using Instruction
1. The height of the machine room should be depended on the equipment¡¯s height and the lifting apparatus, 3-5m ad the effective height in general.
2. To ensure a good ventilation inside of the machine room, the temperature there should not be over 40¡ãC and enough venting temperature holes must be set.
3. When to mount both inlet and outlet pipes of the fire-fighting pump, do not let their weight loading on the pump so as to prevent it against damage and its performance of running from being affected.
4. It is not allowed to mount the control cabinet in the front of the diesel engine¡¯s radiator, otherwise the electric components inside of the cabinet would be affected and not work normally.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.

    Translated with www.DeepL.com/Translator (free version)