Swift Fire Control: EEJ Pump Set

1.Flow: 50-5000GPM
2.Head: 3-20Bar
3.Speed: 740-2900r/min
4.Power: Electric pump: 1.5-710 kw, Jockey pump: 0.55-160kw
The EEJ Fire Pump System is an innovative solution designed to enhance fire safety in various settings. With exceptional performance and efficiency, the EEJ Fire Pump System delivers high pressure and large flow capacity, enabling rapid and effective fire suppression.Overall, the EEJ Fire Pump System is a reliable choice for safeguarding lives and properties, making it an ideal fire protection solution for commercial buildings, industrial facilities, and residential areas.

Rated 4.6/5 based on 297 customer reviews
Share:
Content

Types of pumps include: End Suction Pump,  Split Case Pump, Vertical Inline Pump and Vertical Turbine Pump.

1. Electric motor driven pump, can use single stage pump, horizontal split case pump, end suction pump,multistage pump.

2. Jockey pump, horizontal or vertical, capacity will be small, but head should be higher than electric and diesel engine pump.

3. Control panel: Auto Control of electric pump, diesel engine pump and Jockey Pump with overload, over current protection.

Overall, the EEJ Fire Pump System offers the advantages of reliable operation, high performance, corrosion resistance, intelligent control, and versatile application. These features make it an exceptional choice for enhancing fire safety and protecting lives and properties in diverse settings.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.

    Translated with www.DeepL.com/Translator (free version)