Home » Fire Pump Set » EEDJ Fire pump set for small flow

EEDJ Fire pump set for small flow

EEDJ Fire pump set for small flow is made of E+E+D+J
Operation: 2 Duty (electric) + 1 standby (diesel engine) + 1 Jockey
Capacity: 30, 50, 80, 100, 150 GPM with pressure 4, 5, 6, 8, 10Bar.
Pressure vessel 12, 24liters, pressure will be 0.6mpa, 1.0mpa, 1.6mpa, select according to pump head.

Rated 5/5 based on 324 customer reviews
Share:
Content

Application Scope
Equipment for warehouses, docks, airports, petrochemical, power plants, liquefied gas, textiles, ships, oil tankers and other occasions of a fire service.

Using Instruction
Altitude ≤ 1000m;
Ambient temperature: +5 °C ~ +40 °C;
Relative humidity: <= 90%.

Inquiry


    More Fire Pump Set

    Installing fire pumps requires careful planning and adherence to specific precautions to ensure proper functionality and compliance with safety standards. Here are some important precautions to consider during the installation process:

    Compliance with Codes and Standards: Familiarize yourself with local fire codes, regulations, and industry standards applicable to fire pump installations. Ensure that the installation meets the requirements of organizations such as the National Fire Protection Association (NFPA) and local authorities having jurisdiction (AHJs).

    Professional Installation: Fire pump installations should be carried out by qualified professionals experienced in fire protection systems. Engage licensed contractors or fire protection engineers who specialize in fire pump installations. They possess the necessary knowledge and expertise to ensure a correct and safe installation.

    Proper Location: Choose an appropriate location for the fire pump installation. Consider factors such as accessibility, proximity to water sources, electrical connections, and suitable drainage. The location should allow for easy maintenance and serviceability. Follow the manufacturer’s guidelines regarding clearance requirements and proximity to other equipment.

    By following these precautions, you can ensure a safe and effective installation of a fire pump system. Proper installation is critical for the system’s performance, compliance with regulations, and the overall safety of the facility and its occupants. Consult with fire protection professionals and refer to relevant codes and standards throughout the installation process.

    When facing the fire risks in modern buildings and industrial facilities, firefighting efficiency and reliability are the foremost considerations. Electric fire pumps are the ideal solution for tackling fire challenges in complex environments, offering high efficiency, stability, and smart control systems. Whether in high-rise buildings, industrial parks, chemical plants, or power facilities, electric fire pumps ensure exceptional performance.

    Firstly, electric fire pumps are equipped with high-performance electric motors, ensuring the stable operation of the pump through intelligent control systems. In the event of a fire, the system responds quickly and activates the pump, providing a steady water flow to extinguish the fire. Especially in complex environments such as narrow spaces, high-temperature settings, or areas requiring highly precise control, the electric fire pump continues to operate efficiently, ensuring the successful execution of firefighting tasks.

    Moreover, the smart control system of the electric fire pump continuously monitors the pump’s operational status, conducts self-diagnostics, and adjusts pressure and flow, ensuring no performance degradation during firefighting operations. Its compact design allows it to fit into spaces with limited room while maintaining top-notch performance.

    With the increasing emphasis on environmental protection and energy efficiency, the low energy consumption and high performance of electric fire pumps make them increasingly popular in the market, playing a critical role in optimizing firefighting efficiency.

    The minimum fire rated pressure of ED small fire fighting package set water supply equipment is 3 bar and the minimum fire rated capacity is 25 GPM. ED small fire fighting package set water supply equipment includes at least two power or power source driven pumping units, pressure tanks, pipes, valves and accessories, measurement and control instruments, control cabinets, outdoor rain cover, etc.
    Motor: Three-phase asynchronous squirrel-cage motor independently developed and manufactured by our company, which can be controlled in production time and greatly shorten the whole set production time.
    Diesel Engine: According to the different parameters of customers, we will choose diesel engines with high cost performance ratio. The main brands are QuanChai, Weichai, ShangChai, FAWDE, Cummins, etc.
    Electric Pumps: Electric pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Diesel Pumps: Diesel pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Electronic Components: The main electric components is CHNT, if Schneider or other brand electrical are need, should mention it before place the order.
    Safety Valve plays a safety protection role in the system. When the system pressure exceeds the prescribed value, the safety valve opens, and a part of the gas/fluid in the system is discharged into the atmosphere/pipeline, so that the system pressure does not exceed the allowable value, so as to ensure that the system does not cause accidents due to excessive pressure.
    Pressure Tank: Water is a non-compressible medium. Generally speaking, the pressure drop of fire-fighting pipe network is normal. However, the pressure drop is very slow, the total loss of water in the pipe network isnot large, and the frequent change of pressure in the pipe network leads to frequent start-up and shutdown of pumps. Especially when the power of equipment is high, it will cause great impact on pressure sensors, relaysand motors, thus affecting the performance and life whole equipment. Therefore, it is necessary to choose the right volume of the pressure tank.