Home » Fire Pump Set » UL DJ Fire Pump Set with End Suction fire pump

UL DJ Fire Pump Set with End Suction fire pump

1.Flow:30-9000 GPM
2.Head: 3-20 Bar
The DJ Fire Pump Set is a combination system consisting of a diesel engine pump and a jockey pump, designed for fire safety in the construction and industrial sectors. This system utilizes the powerful power output of the diesel engine pump, ensuring reliable operation even in the event of a power outage.

Rated 4.7/5 based on 357 customer reviews
Share:
Content

Flow:30-9000 GPM

Head: 3-20 Bar  40-300 psi

Power:Diesel & Electric Pump:1.5-710kw  Jockey Pump:0.55-160kw

Speed:740-2900 r/min

Types of pumps used for fire service include: End Suction Pump,  Split Case Pump, Vertical Inline Pump and Vertical Turbine Pump.

1.Diesel engine pump, with capacity and head equal to electric pump, with fuel tank, water tank, fan,control box.

2. Jockey pump, horizontal or vertical, capacity will be small, but head should be higher than electric anddiesel engine pump.

3. Control panel: Auto Control of electric pump, diesel engine pump and Jockey Pump with overload, overcurrent protection.

Inquiry


    More Fire Pump Set

    There are numerous ways to maintain fire pumps and water pumps. The following styles are more effective. You can use them for reference
    System 1 The installation of the pump set should be accurate and dependable, and there should be no egregious vibration duringoperation.However, or the bearing is hot to the touch( the temperature is advanced than 60 °C) and the water seepage in the seal of the pump shaft is further than 60 drops per nanosecond, the cause must be set up out and the fault should be excluded in time, If the pump makes abnormal noise when pumping water.
    the
    system 2 Screws that are squinched daily, similar as packing gland screws, irrigation entrapments,etc., should be disassembled with a suitable wrench and a reasonable necklace. You can put some slicking oil painting on it or wipe it regularly with an oil painting cloth to help rust; if the water drain screw isn’t used constantly, it’s easy to rust, so after buying a new water pump, you should first wind the water drain draw, and apply some machine oil painting and white lead oil painting on the screw thread, Change the new oil painting two or three times a time in the future.
    the
    System 3 If the pump is waxed with machine oil painting, the slicking oil painting should be replaced once a month; if it’s waxed with adulation, it should be replaced every six months. It should be noted that the water pump uses calcium- grounded grease, and the motor uses sodium- grounded grease, and they shouldn’t be used inaptly. Because sodium- grounded grease is hydrophilic, it’ll emulsify into froth and dissipate when it encounters water on the pump, while calcium- grounded grease is hysterical of high temperature, so it’s easy to melt when the temperature rises when used on a motor.

    system 4 Don’t pump water with too important beach, so as to avoid unseasonable wear and tear of the impeller, mouth ring and shaft, and try to help water deficit operation. Running without water will damage the water seal, and the water pump is prone to water leakage or indeed no water.
    System 5 After the irrigation and drainage season is over, the water pump should be precisely gutted and auditedimmediately.However, they should be repaired or replaced in time, and the corridor that should be waxed should be filled with suitable oil painting; Stylish stored in a dry place, If any damaged or misshaped corridor are set up to be unworkable.

    In modern fire protection systems, rapid response to fire incidents is crucial for safeguarding life and property. The Pressure Stabilization and Dual-Function Pump System integrates powerful pressure regulation with dual power sources to ensure that the fire protection system quickly responds and maintains a continuous, stable water supply during emergencies.

    This pump system is designed with two power sources—an electric motor and a diesel engine. When the primary power source fails, the diesel engine automatically starts, ensuring uninterrupted operation of the fire protection system even during power outages. Its pressure stabilization system automatically adjusts pressure during operation, ensuring stable water flow for fire suppression and preventing water interruptions due to insufficient or fluctuating pressure, ultimately improving firefighting efficiency.

    The intelligent control system further enhances the efficiency of the pump system, allowing users to monitor the system’s status in real-time through a touch panel. The system is easy to operate, and any malfunction is quickly detected and alarms are triggered, activating backup systems to effectively prevent emergency issues caused by system failure.

    This pump unit is ideal for applications in high-rise buildings, industrial zones, storage facilities, and other locations with high reliability requirements for fire protection, ensuring that the fire pump can be immediately activated and continue to supply water in any emergency.