SKID MOUNTED FIRE PUMP

Fire-fighting package set water supply equipment manufactured by is referred to as
“dual-power”, “Fire Pump Set” hereinafter as “dual-power”, “Fixed Fire Pump Installation
Standard” and “Standard for the Fixed Fire Pump Installation Standard” of the
American Fire Protection Association in accordance with China Standard GB27898.5-2011
Fixed Fire-fighting Water Supply Equipment Part 5 “Fire Dual-power Installation of
Stationary Pumps for Fire Protection -2016 design and manufacture. Comply with the
latest Chinese national standard CCCF certification requirements and obtain the
certificate. Dual power is one of the reliable products in fire fighting water supply equipment.

Rated 4.5/5 based on 365 customer reviews
Share:
Previous:
Content

Fire-fighting package set water supply equipment manufactured by is referred to as
“dual-power”, “Fire Pump Set” hereinafter as “dual-power”, “Fixed Fire Pump Installation
Standard” and “Standard for the Fixed Fire Pump Installation Standard” of the
American Fire Protection Association in accordance with China Standard GB27898.5-2011
Fixed Fire-fighting Water Supply Equipment Part 5 “Fire Dual-power Installation of
Stationary Pumps for Fire Protection -2016 design and manufacture. Comply with the
latest Chinese national standard CCCF certification requirements and obtain the
certificate. Dual power is one of the reliable products in fire fighting water supply equipment.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.

    Translated with www.DeepL.com/Translator (free version)